Please use this identifier to cite or link to this item: https://hdl.handle.net/1889/1092
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCerioni, Roberto-
dc.contributor.advisorRoyer, Gianni-
dc.contributor.authorSilvestri, Mirko-
dc.date.accessioned2009-06-24T08:14:40Z-
dc.date.available2009-06-24T08:14:40Z-
dc.date.issued2009-
dc.identifier.urihttp://hdl.handle.net/1889/1092-
dc.description.abstractLa tesi di dottorato ha come oggetto principale lo studio e la caratterizzazione del comportamento a flessione di elementi strutturali in vetro stratificato. La progettazione di tali elementi è particolarmente delicata e richiede estrema cura perché la struttura è soggetta al rischio di rotture fragili, sia causate da possibili difetti presenti nel materiale vetro, sia da impatti accidentali anche di lieve entità. Nel lavoro di tesi l’attenzione viene focalizzata soprattutto sul comportamento post critico, cioè sulla caratterizzazione della capacità di questi elementi strutturali di garantire una certa capacità portante anche dopo la rottura del vetro. Questa proprietà risulta fondamentale per raggiungere adeguati livelli di sicurezza. Sono stati analizzati, con prove sperimentali e conseguente modellazione numerica, i fattori che influenzano il comportamento delle lastre sia prima che dopo la rottura del vetro. In particolare vengono trattate le tematiche riguardanti la resistenza del vetro, la risposta meccanica dei materiali polimerici utilizzati come interstrato, il comportamento degli elementi laminati e le differenti tecnologie di fissaggio esistenti. Nello specifico viene presentata un’accurata descrizione delle differenti fasi, dalla ideazione alla modellazione, dalla sperimentazione alle prime realizzazioni, che hanno portato alla concezione di un sistema innovativo di fissaggio puntuale (chiamato “sistema Geco”) per lastre stratificate, ideato con l’obiettivo di ottimizzare il comportamento a flessione e gli aspetti legati alla sicurezza strutturale.en
dc.description.abstractThe use of glass as a structural element in architecture is marked out by the intrinsic brittleness of this material. For this reason, glass plies are usually laminated with polymeric interlayers such as PVB, EVA, SGP. The primary function of the interlayer is to impart to the glass a reliable safety performance: since the fragments remain attached to the polymer even after glass breakage, the system still maintains a certain load bearing capacity even in the post-critical phase. The fragments, kept coherent by these polymeric materials, avoid sudden collapse (fail-safe response), augmenting the stiffness of the system. However, the safety performance is annihilated if the connection to the load-bearing back structure is not able to retain the panels in their place after glass breakage. Fundamental aspects as safety, performance and aesthetic have been considered in the development of an innovative point-fixing device for frameless glazing. In this system, the essential role is played by the use of Dupont’s Sentry Glass Plus (SGP) polymer as interlayer. The conception is original because the metallic part is already integrated with the laminated glass and can be directly connected to any load bearing back structure. In fact, the SGP interlayer, slightly extended beyond the edge of the glass plies in proximity of their borders, is bent at right angle and directly attached to metallic clamps right during the lamination process. The attaching device exhibits a noteworthy resistance and interesting post-glass-breakage performances, since collapse of the panel may be prevented even when the glass plies are completely fragmented because this is directly attached through the polymer interlayer. Static and cyclic tests have been performed on small scale glass beams at various room temperatures and aging level. Bending tests on full scale glass plies confirm the results obtained on smaller specimens and the optimal post critical behavior of this point fixing-system. Results of these tests and practical applications of this new connection to recently-built glass-façades are illustrated.en
dc.language.isoItalianoen
dc.publisherUniversità degli Studi di Parma. Dipartimento di Ingegneria Civile ed Architetturaen
dc.relation.ispartofseriesDottorato di ricerca in Ingegneria Civileen
dc.rightsMirko Silvestri, ©2009en
dc.subjectframeless glazingen
dc.subjectpoint fixingen
dc.subjectlaminated glassen
dc.subjectfaçadeen
dc.titleSul comportamento post critico di pannelli in vetro stratificatoen
dc.title.alternativeOn the post-critical behavior of laminated glass structural elementsen
dc.typeDoctoral thesisen
dc.subject.soggettarioVetro - Proprietàen
dc.subject.miurICAR 08en
dc.subject.miurICAR 09en
dc.description.fulltextrestricteden
Appears in Collections:Ingegneria civile, dell'Ambiente, del Territorio e Architettura. Tesi di dottorato

Files in This Item:
File Description SizeFormat 
Silvestri_A.pdf
  Until 2101-01-01
Tesi Dottorato Silvestri pag0-7510.14 MBAdobe PDFView/Open Request a copy
Silvestri_B.pdf
  Until 2101-01-01
Tesi Dottorato Silvestri pag76-14515.23 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.